youTube Twitter

Global

Global

07 May: Climaveneta@AIHL
26 April: new video Climaveneta@LeAlbere on Youtube Channel
22 April: Climaveneta HVAC units serving the new LEED gold certified Unicredit headquarters in Milan
Fiera
  • May 30th, 2013 | Milan
Fiera
  • May 21st, 2013 | Kuala Lumpur
Fiera
  • Climaveneta partner of Progetto HORECA for Smart&Green Hotel
Fiera
  • Klimahouse 2013
    January 24th-27th, 2013 | Bozen
Sustain Premium

Climaveneta for Middle East

Air conditioning beyond traditional technological frontiers

The awareness of the huge challenges an air conditioning system has to cope with in Middle East and the extensive experience in this market has led Climaveneta to concentrate all its know-how to offer a no compromises solution to the most critical factors in this area:

Energy

Energy efficiency

Especially at latitude where the air conditioning systems operate all the year round, even the slightest improvement in the efficiency of the air conditioning system allows large savings in the running costs and a faster return on investments.

Energy

High outdoor air temperature

With outdoor air temperature beyond 35°C many days a year, even the best performing air conditioning system can stop working, exactly when heat loads are at their peak, thus dramatically compromising both quality of comfort and usability of the building.

 

Case study

Energy efficiency and High outdoor air temperature: the true challenges in Middle East air conditioning.

The harsh climate conditions typical of Middle East areas make energy efficiency and extended operating limits even more crucial factors than usual for a effective air conditioning solution.

Graph 1 shows that the yearly average externail air temperature in a typical UAE city is 27°C. Moreover, (graph 2) for six months a year the temperature is above 35°C for 30% of the time.Considering that air-conditioning is needed starting from an external air temperature of 20°C, or even at lower temperatures in many applications such as shopping centres and glas facades buildings, the system runs for over 80% of the year as highlighted in Graph 3.

With yearly operation time of 7.000hours, in case of a 700kWh installation, an EER increase by 5% would mean over 80.000kW/h saved over the whole year. Hence in these conditions even the slightest increase in efficiency drammatically contributes to reduce the running costs and to shorten the pay
back of the system.

Graph n.1 - Average yearly external air temperature Abu Dhabi (source: TRY, Swiss Institute "meteo test")

Graph n.2 - Yearly operating time of the air conditioning system with extremely high external air temperature Abu Dhabi.

Graph n.3 - Yearly operating time of an air conditioning system in Abu Dhabi.

Climaveneta uses cookies for functional and analytical purposes. Please read our Privacy Policy for more information